XML Feed for RxPG News   Add RxPG News Headlines to My Yahoo!   Javascript Syndication for RxPG News

Research Health World General
 
  Home
 
 Latest Research
 Cancer
 Psychiatry
 Genetics
 Surgery
 Aging
 Ophthalmology
 Gynaecology
 Neurosciences
 Pharmacology
 Cardiology
 Obstetrics
 Infectious Diseases
 Respiratory Medicine
 Pathology
 Endocrinology
 Immunology
 Nephrology
 Gastroenterology
 Biotechnology
 Radiology
 Dermatology
 Microbiology
  Virology
   West Nile Virus
  Bacteriology
 Haematology
 Dental
 ENT
 Environment
 Embryology
 Orthopedics
 Metabolism
 Anaethesia
 Paediatrics
 Public Health
 Urology
 Musculoskeletal
 Clinical Trials
 Physiology
 Biochemistry
 Cytology
 Traumatology
 Rheumatology
 
 Medical News
 Health
 Opinion
 Healthcare
 Professionals
 Launch
 Awards & Prizes
 
 Careers
 Medical
 Nursing
 Dental
 
 Special Topics
 Euthanasia
 Ethics
 Evolution
 Odd Medical News
 Feature
 
 World News
 Tsunami
 Epidemics
 Climate
 Business
Search

Last Updated: Aug 19th, 2006 - 22:18:38

Virology Channel
subscribe to Virology newsletter

Latest Research : Microbiology : Virology

   DISCUSS   |   EMAIL   |   PRINT
Mass spectrometry to detect norovirus particles
Apr 10, 2006, 14:08, Reviewed by: Dr. Priya Saxena

"This is a significant step towards using mass spectrometry as an environmental surveillance tool for the detection of pathogenic human viruses in complex environmental samples such as human and animal waste."

 
Scientists have used mass spectrometry for decades to determine the chemical composition of samples but rarely has it been used to identify viruses, and never in complex environmental samples. Researchers at the Johns Hopkins Bloomberg School of Public Health recently demonstrated that proteomic mass spectrometry has the potential to be applied for this purpose. Using a two-step process, researchers successfully separated, purified and concentrated a norovirus surrogate from a clinical sample within a few hours. Nanospray mass spectrometry was used to demonstrate the feasibility of detecting norovirus particles in the purified concentrates.

Human norovirus is responsible for an estimated 23 million cases of gastrointestinal illness in the United States each year. This pathogen is a particular problem aboard cruise ships. The researchers believe that their mass spectrometric method could potentially be used for biodefense and public health preparedness as a tool for rapidly detecting norovirus--a category B bioterrorism agent--and other viral public health threats. The study is published in the April 2006 edition of Applied and Environmental Microbiology.

In simplified terms, mass spectrometry is essentially a scale for weighing molecules. A laser turns a sample into ionized particles, which are then accelerated in a vacuum toward a detector. The time lapsed prior to registering on the detector helps researchers determine the mass--or weight--of the particles. By targeting characteristic particles, or peptides, belonging to the viral coat protein, the virus can be positively identified by matching the results to entries in genetic databases.

In the Hopkins study, the researchers analyzed a stool sample treated with virus-like particles, which closely resemble norovirus but are noninfectious. Using mass spectrometry, the researchers were able to detect the norovirus capsid protein down to levels typically found in clinical specimens from sick individuals.

"This is the first report of the use of mass spectrometry for the detection of norovirus," said David R. Colquhoun, lead author of the study and research fellow with the Johns Hopkins Center for a Livable Future. "This is a significant step towards using mass spectrometry as an environmental surveillance tool for the detection of pathogenic human viruses in complex environmental samples such as human and animal waste."

Typically, bacteria and viruses are identified by cultivation on selective media and cell lines. However, this process does not work for human norovirus, which cannot be cultured outside the human body.

Rolf Halden, PhD, assistant professor in the Department of Environmental Health Sciences and senior author of the study, pointed out that proteomic mass spectrometry is appealing because it has the potential to identify different types and strains of viruses regardless of whether their presence is suspected or not. "Unlike other processes, we do not need to know what we are looking for in advance. Any pathogen whose genetic information is contained in online genetic databases represents a suitable potential target. This makes the technique ideal for situations where you have an emerging infectious agent or pathogenic strain, such as in a potential terrorist attack," said Halden.
 

- The study is published in the April 2006 edition of Applied and Environmental Microbiology.
 

www.jhsph.edu

 
Subscribe to Virology Newsletter
E-mail Address:

 

Authors David R. Colquhoun, Kellogg J. Schwab and Rolf U. Halden are with the Department of Environmental Health Sciences at the Johns Hopkins Bloomberg School of Public Health. Robert N. Cole is the director of the Mass Spectrometry and Proteomics Facility at the Johns Hopkins School of Medicine.

Funding for the study was provided in part by grants from the Johns Hopkins Center for a Livable Future and the National Institute of Environmental Health Sciences.


Related Virology News

How West Nile virus evades immune defenses
Innovative method for creating a human cytomegalovirus vaccine outlined
Cracking Virus Protection Shield
Viruses trade-off between survival and reproduction
New hybrid virus provides targeted molecular imaging of cancer
Mass spectrometry to detect norovirus particles
xCT molecule is a major gateway for KSHV to enter human cells
Surprising discovery about the inner workings of vesicular stomatitis virus (VSV)
New human retrovirus - Xenotropic MuLV-related virus (XMRV)
Viruses can be forced to evolve as better delivery vehicles for gene therapy


For any corrections of factual information, to contact the editors or to send any medical news or health news press releases, use feedback form

Top of Page

 

© Copyright 2004 onwards by RxPG Medical Solutions Private Limited
Contact Us